Skip to content

Troubleshoot A Machine ​

When a machine is misbehaving, the troubleshoot page in the mobile app shows what is wrong with it and why, in one place: what is open, what has been happening, what the checks last said, and whether those results can still be trusted.

It is built for Managers and Team Leaders standing at the machine. To review a machine's performance over weeks or months, use Activity instead.

Open The Page ​

  1. Open the Continual mobile app and select the correct factory.
  2. Open the Troubleshoot tab.
  3. Choose the Line / group at the top of the screen. Machines or assets only appear after you choose a location.
  4. Pick the machine or asset you are standing at.

The selected location stays visible above the list. To troubleshoot equipment elsewhere, change the selector first. Returning from a machine page keeps your selection; switching to another tab or factory clears it, so you choose your location again when you return. Even if you have only one assigned Line or Group, select it before opening a machine.

The page opens with the format the machine is running, for example 500ml PET. Every target depends on the format, and a changeover is the first thing to rule in or out. To change the format, use the format selector on the Checks tab, not this page.

Below it, one line says whether anything is wrong:

  • Needs attention when there are open problems, off-target settings or failed CILs, with what was found, for example 3 open problems · 1 setting off target · 3 settings to re-check.
  • Nothing open when nothing is wrong. It still lists what is owed, such as settings or CILs to re-check (anything its section marks amber) or overdue checks, or says Every check is current.

The line is counted from the sections below it, so the two always agree. Underneath it, the due checks are counted separately from the overdue ones, for example 4 due · 2 overdue for six checks waiting. Tap Go to due checks to work through them.

Machine Summary ​

Each machine or asset in the Troubleshoot directory shows its active check count and open action count. Actions awaiting verification appear separately. Due checks include overdue checks and match the work you can execute on the machine's due-check page, including its format and function restrictions. Overdue counts and open actions stand out in red.

On iPhone, the counts wrap beneath the machine name; on iPad, they appear inside each machine card. A machine with no checks says No checks configured. The coloured bar shows the latest status of active checks that record pass/fail results: green is current and passing, red is current and failing, and amber needs checking (never checked, skipped, stale, or recorded before a relevant format change). Data Capture checks do not record a verdict and are excluded from the bar. The machine page uses the same freshness rules. These are check statuses and work counts, not a machine health score: No checks due does not mean its last results passed.

Returning from a machine or pulling to refresh updates the counts. If the counts cannot load, Counts unavailable and Retry counts appear; you can still open the machine.

On iPad ​

After choosing a Line or Group, machines appear in a grid: two columns in a compact window and three in a wide window. Sequence numbers follow the production order; assets in Groups have no sequence numbers.

On wide iPad windows, Open Problems, What Changed and Manuals sit beside the wider column of Centrelines, CILs and Readings. When the Assistant is enabled, Troubleshoot with AI sits beside the format at the top. In compact windows, Open Problems and What Changed sit side by side above the full-width machine state and manuals.

The layout adapts when you rotate the iPad or resize its window. Narrow windows and larger accessibility text use a single column. The iPhone keeps its single-column list and machine-page layout.

Open Problems ​

Every action on the machine that is not yet closed, whatever raised it:

TagMeaning
DeviationA centreline reading was out of target. The row shows the reading against the target.
DefectA CIL check failed.
Raised by handSomeone created the action manually.
ReviewA temporary target trial is waiting for a verdict. See Deviations And Temporary Target Trials.

Each row shows how long the problem has been open. If it was escalated to your CMMS, the row also shows the CMMS reference, for example In CMMS · WO 48213. When the same check keeps going out, the problem says so, for example 4th time this week · recovered on its own 3×. Problems are listed oldest first.

Problems that have been fixed and are waiting for their check to pass are folded into one line, for example 1 fix awaiting verification. Tap it to show them.

Tap a problem to open the action. When nothing is open, the section does not appear.

What Changed ​

Most deviations close themselves on the next good reading, so the open list is often empty while the machine has still been struggling. What Changed shows the last 7 days, newest first, under day headings:

  • Problems raised and closed. A problem that keeps coming back is grouped into one line, for example "Cap torque deviated 4× this week. Recovered on its own 3 times." A problem someone resolved shows its root cause and resolution note.
  • Failed checks that did not raise an action, with the operator's note.
  • Format changes that changed this machine's format. A changeover that left this machine as it was does not appear.
  • Target changes and temporary target trials on the machine's checks.

Anything already shown under Open Problems is left out here, so each fact appears once. The page shows the latest six changes. Tap See all for every event in the week, including the open problems. Tap any event about an action to open it.

Centrelines ​

Each setting shows its last reading on the right, and below it the target for the format running now and the reading's status:

StatusMeaning
Off targetThe last reading was outside the target.
Before format changeThe last reading was taken before the machine last changed format, so it describes a setting for a different format.
StaleNo reading for more than two of the check's scheduled intervals.
In targetThe last reading was within the target, and it is recent.

Centrelines start closed, as one line of counts, for example 1 off target, 2 stale, 4 in target, or All N in target. Tap it to show every setting in the machine's check order.

A dot beside the arrow uses the same colours as the bar in the machine list: red if any check's latest result failed, amber if any needs checking (never checked, skipped, stale, or recorded before a format change), and green when every check is current and passing. The CILs line has the same dot.

When a centreline's target is a photo, the row shows a thumbnail. Tap it to open the target image full screen, together with the last reading's photo if there is one, and zoom in.

To read settings again after a changeover, use Trigger all checks in the ⋯ menu; see Trigger All Checks.

CILs ​

CILs are summed up in one line, for example 1 failed, 1 stale, 4 passed, or All N passed. Tap it to show each CIL with its last result and how long ago it was done. A stale result also says what it last was, for example Passed 9 d ago.

Readings ​

On machines whose HMI screens are photographed by Data Capture checks, Readings comes after the checks: what the machine's screens report. The heading says which screen the readings come from and when it was last captured.

Each reading shows its latest value, its recent trend and how old it is. Readings that are still being validated, or that failed validation, are shown in grey with Validating or Chart only. If the latest photo could not be read, the row says Latest photo not read, so an old value never looks current. Tap a reading to open its chart.

Screens and photos opens each screen's capture history and photo problems. If photos from a screen are having problems, the link says so.

Manuals ​

The machine's uploaded manuals. Tap one to open it in the in-app PDF viewer. The section only appears when the machine has a manual.

Troubleshoot With AI ​

If the Assistant is enabled for your organisation, tap Troubleshoot with AI. On iPhone it floats at the bottom right of the page. The chat opens scoped to this machine. It offers up to three starting questions based on what the page shows:

  1. The first off-target centreline, for example "Cap torque is reading 14 Nm against 16–18 Nm. What should I check?"
  2. A problem that keeps recurring.
  3. The oldest open problem.

Each question shows why it is suggested. Tap one to send it, or type your own. A machine with nothing wrong gets general starting questions instead. See AI Assistant for what the Assistant can do.

New check, New action and Trigger all checks are in the ⋯ menu at the top right.